ident
All repositories: gitoria
3.3 KB
\* Timer.hl → class Timer — ONE clock event source, its lifetime, its events.`every(n)`, `after(n)` and `until(t)` all hand back one of these. The eventloop wiring lives HERE so app code never sees it: the source is registered ATthis instance, the internal fan-out re-emits `tick` at itself, and`on interval.tick()` in the app is an ordinary instance-scoped handler — thesame shape hl:proc's Process has carried since 2026-08-17.let interval = every(360)on interval.tick(t) { … } \\ t = { count, at }interval.stop()ONE EVENT NAME FOR ALL THREE. `after(n)` IS `every(n)` that fires once and`until(t)` IS `after(t - now())`; one primitive, two conveniences. Naming theone-shot's event `finished` or `isUp` would mean swapping the constructorforces rewriting the handler, and this language's events are verbs of arrival— `line`, `exit`, `chunk`, `ready`, `saved`, `tick`. *\\* The interval this timer was created with, in seconds (raised to hl:time'sfloor if it was written below it — see server.hl). *\Number seconds = 0\* True for `every()`; false for the one-shots `after()` and `until()`. *\Boolean repeating = false\* False once a one-shot has fired or `stop()` was called. An `every` whose`running` is true keeps the program alive — that is the point of it. *\Boolean running = false\* How many ticks have been delivered. 1 on a one-shot's only tick. *\Number count = 0Number #id = 0Number #srcId = 0\* Arm the timer and register its source. Called by `every`/`after`/`until`;there is no reason to call it yourself. *\start(Number secs, Boolean repeat) {let armed = __native("time.timer", secs, repeat)#id = armed.idseconds = secsrepeating = repeatrunning = true#srcId = __native("eventloop.register", armed.events, "__timerTick")// ONE TICK AT A TIME (ticket #159): a tick handler that waits (a fetch parks its fiber and the// loop runs the others) is not entered again by this clock; the next tick comes once it returned// (a LITERAL op, NativeCompile.hl `nativeCall` → hl_eventloop_serial: a computed one would make// every program importing hl:time, the compiler too, link dynamic — ticket #165)__native("eventloop.serial", #srcId)return this}on __timerTick(ev) {count = ev.countif (repeating == false) {// A SPENT ONE-SHOT RETIRES ITS SOURCE, BEFORE the tick is emitted.// Mission 249 found the same defect in hl:proc on 2026-08-29: a child// that had exited left its source registered, so the loop still held// something that would never speak again and NO hl:proc program could// ever end. An `after()` that does not retire hangs every program that// uses one, which is why the test for this asserts TERMINATION and not// output.running = false__native("eventloop.unregister", #srcId)__native("time.timer_stop", #id)}emit tick(ev)return null}\* Stop an interval (and end the program, if it was the only thing keeping italive) — the counterpart of `server.kill()`. True when this call was the onethat stopped it; false if it had already fired or been stopped. *\stop() {if (running == false) {return false}running = false// ORDER IS LOAD-BEARING: retire the source first, so the loop has dropped// this fd from its epoll set before the fd is closed.__native("eventloop.unregister", #srcId)__native("time.timer_stop", #id)return true}
Branches
Latest commits
- 80965c08ident#28: README says the deploy goes through the standbymre
- 2f41670cident#28: ident-standby service on port 45012 (no background round in the standby) and deploy.sh hands over through standby-swap.shmre
- a544b261ident#28: README names the new vendored Hybrielmre
- 716860b0ident#28: gates follow Hybriel ac1ed9da (lazy sessions, meta attribute order, JSON key order, default X-Frame-Options switched off for the embed page)mre
- 889e00fbident#28: Hybriel master ac1ed9da (sessions reload a newer file, a replayed reconnect carries the server session); a startup fault exits 1 (on Error)mre
- f5a55f8aident#11: apps can ask for nickname, firstname and lastname (fields list on /api/exchange, new POST /api/profile); empty fields come back null; gate checks, READMEmre
- d8be66ebident: report and log line for the widget cache and frame height changemre
- 2068f61aident#31: browsers revalidate the widget scripts on every load; the sign-in frame is exactly as tall as the current step (the frame page reports its height, selector.js accepts it from ident only)mre
- a22d2daaident#31: the sign-in frame is no taller than the tallest step needs (plain CSS height per width), gate check for itmre
- a77d1b22ident#31: the welcome form keeps editId a plain value (browser gate), README, wider rows in the framemre
- 5c481bfdident#31: sign in to ident inside the selector's panel (email, code, identity in an iframe; a new address goes to ident in the same tab and comes back)mre
- 061abfe2ident: the apps gate waits until the test app's login button stops moving before it clicks (the page grows after load and the click missed about every second run)mre
- 45f7e4daident: the user menu's Sign out waits for the server before it reloads (the apps gate failed because the session could still be signed in)mre
- f07658c7ident: home page shows the account once (account bar removed, the user menu carries email, Sign out, Sign out everywhere); wildcard origins https://*.domain for apps on many subdomains; gates follow (WIP: gates not re-run after the last edits)mre
- f2c43bbbtheme: sync from layouts 4994037 (list rows stack, td word-keep, heading code, edited tap target)mre
- 6d4f996esessions last 99 years (creator 2026-10-23: logins never expire; only sign out ends them)mre
- 029eb5e5deploy: security gate (tests/security.mjs)mre
- d3c065a8security audit (SI): uploadMax 0, Secure __Host- cookie behind https, headers on function routes/files, page CSP+referrer meta, app/identity caps, tests/security.mjs, reportmre
- 5561a0cbreport I4-mobilemre
- 4ca2ed20404 page in the shell (viewport, status 404, way home); phone: account actions live in the user menu so the open menu covers nothing; mobile gate; signoutall waits for a cold startmre